The Multi-Layer Technique

Prof. Dr. Hannes Wachtel
Initial situation

A male patient (68 years old) shows a fistula and root fracture in position 21

Used biomaterials
  • mp3®
  • Lamina®
1. Patient received implants #12 and #11 in 2001. Tooth #21 is failing, presenting a fistula and a root fracture. Note the vertical discrepancy of the gingival and incisal line

1. Patient received implants #12 and #11 in 2001. Tooth #21 is failing, presenting a fistula and a root fracture. Note the vertical discrepancy of the gingival and incisal line

2. Panoramic view before treatment. #21 not maintainable presenting a large apical lesion

2. Panoramic view before treatment. #21 not maintainable presenting a large apical lesion

3. Immediate implant placement and reconstruction of the missing buccal bony plate with a OsteoBiol® Lamina® Soft and CT graft. The gap is filled with OsteoBiol® mp3®

3. Immediate implant placement and reconstruction of the missing buccal bony plate with a OsteoBiol® Lamina® Soft and CT graft. The gap is filled with OsteoBiol® mp3®

4. Frontal view immediately after surgery and inserting the temporary bridge

4. Frontal view immediately after surgery and inserting the temporary bridge

5. X-ray of the 3 implants: #12 and #11 18 years old - #21 implantation according to the Multi Layer Technique (MLT)

5. X-ray of the 3 implants: #12 and #11 18 years old - #21 implantation according to the Multi Layer Technique (MLT)

6. Final treatment result after extraction of tooth #21, implantation, immediate restoration and site development according to the Multi Layer Technique (MLT) and new full ceramic crowns #12 - #22

6. Final treatment result after extraction of tooth #21, implantation, immediate restoration and site development according to the Multi Layer Technique (MLT) and new full ceramic crowns #12 - #22

Used biomaterials
mp3
mp3®
lamina
Lamina®
Are you a medical professional?
No

Attention please! The OsteoBiol® website contains information on Medical Devices, which may be dangerous for the patient health and safety if not used exclusively by medical professionals.